Distributed by:
Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology
Conductivity Type Liquid Level Controls: LC Series
Single Level Control - 2 Probes
Model Number |
Probe Length (Field Trim) In./(mm) |
Probe Shipping Weight Lb./(Kg) |
2 ( * ) 6 |
6 (155) |
3 (1.5) |
2 ( * ) 12 |
12 (305) |
3 (1.5) |
2 ( * ) 18 |
18 (460) |
4 (2) |
2 ( * ) 24 |
24 (610) |
6 (2.5) |
2 ( * ) 30 |
30 (762) |
7 (3) |
2 ( * ) 36 |
36 (915) |
8 (3.5) |
2 ( * ) 48 |
48 (1220) |
9 (4) |
Two Level Control - 3 Probes
Model Number |
Probe Length (Field Trim) In./(mm) |
Probe Shipping Weight Lb./(Kg) |
3 ( * ) 6 |
6 (155) |
3 (1.5) |
3 ( * ) 12 |
12 (305) |
3 (1.5) |
3 ( * ) 18 |
18 (460) |
4 (2) |
3 ( * ) 24 |
24 (610) |
6 (2.5) |
3 ( * ) 30 |
30 (762) |
7 (3) |
3 ( * ) 36 |
36 (915) |
8 (3.5) |
3 ( * ) 48 |
48 (1220) |
9 (4) |
COMPONENTS PURCHASED SEPARATELY - SPECIFY PROBE MATERIAL:
- S=Stainless Steel.
- H=Hastelloy C®.
- T=Titanium.
- G=Graphite-tipped
- Fluoropolymer (PTFE) covered standard
IMPROVES PROCESS CONTROL:
- Provides automated control and consistent liquid levels in most conductive aqueous processes, waste treatment tanks and when leak detection is required.
- Adds protection against fires and tank damage associated with low-level conditions.
- Dual probe units (LC2): for single point control.
- Multi probe units (LC3): for two-point control and refill/pump down applications.
CORROSION RESISTANT PROBES:
- Fluoropolymer (PTFE) covered: 316 stainless steel, titanium, Hastelloy C® and graphite tipped Hastelloy probe materials.
- Lengths: up to 48 inches (1220mm) standard.
- Field trimmable (except graphite probes).
CORROSION RESISTANT ENCLOSURES:
- Control enclosure: gasketed UL Type 4/4x, IP62 (indoor) polypropylene box with stainless steel hardware.
- Probe enclosure: vapor resistant polypropylene head with 10-foot (3m) flexible lead and quick connect plug for easy connection to remote circuitry.
CERTIFICATIONS:
CAPACITIES:
- Relay rating: 10-amps at 120/208 to 240 volts, 50/60 Hz, single pole, double throw.
- Sensing output: 14.5 VAC.
- Ambient temperature range: 0°F (-18°C) to 104°F (40°C).
- Maximum solution resistance: 70,000 ohm-CM.
- Single phase only.
SAFETY FEATURES:
- Ground connection on circuit board.
- Minimal AC sensing current has no affect on plating processes.
CONSULT FACTORY FOR THE FOLLOWING OPTIONS:
- Probe lengths up to 20-foot (6m).
- Can be pre-wired into combination controls.
- Fluid stilling chambers.
- Longer flexible cords.
- Cord extensions for existing units.
- 4, 5 or 6-probe devices for multiple level control applications.
NOTE:
- Do not use in flammable solutions or in the presence of flammable gases. Not for use in deionized water, oil or other non-conductive solutions.
Downloads: