							Distributed by:
							
							Equipment Overview | Filter Pump Industries / Penguin Pump  | Process Technology
							 
							
							
							XC Series, Inline Fluoropolymer Heat Exchanger
					
					
					
  					Rugged inline heat exchangers ideal for one pass cooling of chemicals dumping to waste stream.  This product is also appropriate for heating applications.  Eliminates high costs associated with water aspiration.  
					PP or PVDF housing and fluoropolymer tubing.  Custom configured for your application.  Custom sizes available, please contact factory for sizing assistance.  XC in-line heat exchanger shown (cutaway for illustrative purposes).
	  
	  	
			
			Specifications
		
			SERVICE: 
			- In-line chemical heat exchanger with all  fluoropolymer wetted surfaces (tubing side) for virtually any wet chemistry  application.
 
			
			
            SIZES: 
			
			- 1.5 ft2 (.14m2) of exchange area
 
			- 2.5 ft2 (.23m2) of exchange area
 
			- 3.5 ft2 (.33m2) of exchange area
  
			
	
			
			
            STANDARD FEATURES: 
			
			- ½-inch  (12mm) heavy wall PFA tubing, .030” (.76mm) thick
 
			- All welded  construction (shell)
 
			- 4½-inch  (114mm) diameter polypropylene shell
 
			- Internally  baffled for enhanced heat exchanger performance
 
			- “U” factor  (depending on flow rate): 25-50 BTU/(hr x ft2 x °F) = 142-284 J/(s x m2 x °C)
 
			- Shell-side  drain connection
 
			
			
			
            FLUID CONNECTIONS: 
			
			- Fluid  (tube): ½-inch (12mm) male flare PFA
 
			- Shell: ¾-inch  (19mm) male flare PFA
 
			- Shell  drain: ¼-inch (6mm) male flare PFA
 
			
 	
			
			
            MAXIMUM PRESSURE / TEMPERATURE: 
			
			- Tube (PFA):  35 PSIG (241 kPa) at 120ºC (250ºF)
 
			- Shell (PP):  30 PSIG (206 kPa) at 82ºC (180ºF)
 
			- Optional  shell (PVDF): 30 PSIG (206 kPa) at 135ºC (275ºF)
  
			
	
			
			
            WARRANTY: 
			
			
			
			Features and Benefits
			
			SUPERIOR CHEMICAL RESISTANCE: 
			- All tube-side parts are fluoropolymer and compatible  with most chemistries for virtually unlimited process options.  Shell is available in polypropylene  (standard) or PVDF construction.
 
            
			
            RUGGED CONSTRUCTION: 
			- Thick wall, welded construction provides extremely  long service life. 
 
			
          
          OUTSTANDING PERFORMANCE: 
		  	
- Heavy wall, large diameter tubing improves  circulation and minimizes pressure drop.
 
			
          
          LEAK-FREE OPERATION: 
		  	
- Integral inlet/outlet for single point fluid  connections simplifies installation and greatly reduces the potential for chemical  leaks.
 
          
          
          COMPACT SIZE: 
		  
- Less surface  area required for same BTU exchange compared to most other fluoropolymer  exchangers.
 
		  
		  
          CONSULT FACTORY FOR THE FOLLOWING OPTIONS:
          
		  - ¼-inch  (6.4mm) to ¾-inch (19mm) Super Pillar 300 Type® connections
 
          - Custom  sizes based on application
 
          - PVDF shell
 
		  - Vacuum breakers are recommended for steam heating applications.  Please consult factory for reduced pressure steam applications.  Pulsation dampeners recommended.
 
		  
		  
           
        
        