Distributed by:
Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology
NR Series, Non-indicating Thermostats
MODEL NUMBER |
VOLTS |
MAX. AMPS |
TEMP. RANGE |
SENSOR LENGTH Ft./(m) |
REPL. SENSOR P/N |
SHIP WGT. Lbs./(kg) |
NR25 |
120/240 |
25* |
30 °F - 220 °F |
5' (1.5m) |
NR25-5L |
3 (1.5) |
NR25-12 |
120/240 |
25* |
30 °F - 220 °F |
12' (3.7m) |
NR25-12L |
3 (1.5) |
NR25H |
120/240 |
25* |
200 °F - 550 °F |
5' (1.5m) |
NR25H-5L |
3 (1.5) |
Features and Benefits
IMPROVES PROCESS CONTROL:
- Large, easy to read dial. Provides general control and consistent plating and etch rates in most aqueous processes.
TEMPERATURE SENSOR:
- Fluoropolymer (FEP) covered 5-foot (1.5m) copper bulb and capillary provided standard with the control. Provides extended service in corrosive liquids. Ethylene glycol filled system.
CORROSION RESISTANT ENCLOSURE:
- Vapor tight, NEMA 1, IP23, flame retardant gasketed plastic enclosure with stainless steel hardware.
CERTIFICATIONS:
CAPACITIES:
- Double pole, single throw switches rated at 25 amps for either 120 or 240 volts.
- Adjustable temperature range from 30°F to 220°F.
- +/- 5°F accuracy.
- 30°F (-1°C) to 150°F (65°C) ambient temperature range.
- Single phase only.
SAFETY FEATURES:
- Pre-wired P1 terminal blocks.
- Ground connection on thermostat.
CONSULT FACTORY FOR THE FOLLOWING OPTIONS:
- 12-foot (3.6m) sensors.
- Combination controls available for three phase service and larger heater loads.
- Pre-wired outlets for plug-in heaters.
- 200°F to 550°F temperature range.
Downloads: