							Distributed by:
							
							Equipment Overview | Filter Pump Industries / Penguin Pump  | Process Technology
							 
							
							
							Conductivity Type Liquid Level Controls: LC Series
					
					
					
                     Single Level Control - 2 Probes
					
                    
                    
                    
                      | Model Number | 
                      Probe Length (Field Trim) In./(mm) | 
					  Probe Shipping Weight Lb./(Kg) | 
                    
                    
                    
                    
                      | 2 ( * ) 6 | 
                      6 (155) | 
					  3 (1.5) | 
                    
					
                      | 2 ( * ) 12 | 
                      12 (305) | 
					  3 (1.5) | 
                    
					
                      | 2 ( * ) 18 | 
                      18 (460) | 
					  4 (2) | 
                    
					
                      | 2 ( * ) 24 | 
                      24 (610) | 
					  6 (2.5) | 
                    
					
                      | 2 ( * ) 30 | 
                      30 (762) | 
					  7 (3) | 
                    
					
                      | 2 ( * ) 36 | 
                      36 (915) | 
					  8 (3.5) | 
                    
					
                      | 2 ( * ) 48 | 
                      48 (1220) | 
					  9 (4) | 
                    
					
					
					
					 Two Level Control - 3 Probes
					
                    
                    
                    
                      | Model Number | 
                      Probe Length (Field Trim) In./(mm) | 
					  Probe Shipping Weight Lb./(Kg) | 
                    
                    
                    
                    
                      | 3 ( * ) 6 | 
                      6 (155) | 
					  3 (1.5) | 
                    
					
                      | 3 ( * ) 12 | 
                      12 (305) | 
					  3 (1.5) | 
                    
					
                      | 3 ( * ) 18 | 
                      18 (460) | 
					  4 (2) | 
                    
					
                      | 3 ( * ) 24 | 
                      24 (610) | 
					  6 (2.5) | 
                    
					
                      | 3 ( * ) 30 | 
                      30 (762) | 
					  7 (3) | 
                    
					
                      | 3 ( * ) 36 | 
                      36 (915) | 
					  8 (3.5) | 
                    
					
                      | 3 ( * ) 48 | 
                      48 (1220) | 
					  9 (4) | 
                    
					
					
					
	  			
			COMPONENTS PURCHASED SEPARATELY - SPECIFY PROBE MATERIAL: 
			
			- S=Stainless Steel.
 
			- H=Hastelloy C®.
 
			- T=Titanium.
 
			- G=Graphite-tipped
 
			- Fluoropolymer (PTFE) covered standard
 
			
			
          
            IMPROVES PROCESS CONTROL: 
			
			- Provides automated control and consistent  liquid levels in most conductive aqueous processes, waste treatment tanks and  when leak detection is required. 
 
			- Adds protection against fires and tank  damage associated with low-level conditions. 
 
			- Dual probe units (LC2): for single point  control. 
 
			- Multi probe units (LC3): for two-point  control and refill/pump down applications. 
 
			
			
          
          CORROSION RESISTANT PROBES: 
		  	
			- Fluoropolymer (PTFE) covered: 316 stainless  steel, titanium, Hastelloy C® and  graphite tipped Hastelloy probe materials.
 
          	- Lengths: up to 48 inches (1220mm) standard.
 
			- Field trimmable (except graphite probes).
 
			
		  
		  
          CORROSION RESISTANT ENCLOSURES:  
          
		  - Control enclosure: gasketed UL Type 4/4x,  IP62 (indoor) polypropylene box with stainless  steel hardware.
 
          - Probe enclosure: vapor resistant polypropylene  head with 10-foot (3m) flexible lead and quick connect plug for easy connection  to remote circuitry.
 
		  
		  
          
          CERTIFICATIONS:  
          
		  
		  
          CAPACITIES:  
          
		  - Relay rating: 10-amps at 120/208 to 240  volts, 50/60 Hz, single pole, double throw.
 
          - Sensing output: 14.5 VAC.
 
		  - Ambient temperature range: 0°F (-18°C) to  104°F (40°C).
 
          - Maximum solution resistance: 70,000  ohm-CM.
 
		  - Single phase only.
 
		  
          
          
          SAFETY FEATURES:  
          
		  - Ground  connection on circuit board.
 
          - Minimal AC sensing current has no affect on  plating processes.
 
		  
          
		  
          CONSULT FACTORY FOR THE FOLLOWING OPTIONS:
            
			- Probe  lengths up to 20-foot (6m).
 
            - Can  be pre-wired into combination controls.
 
            - Fluid  stilling chambers.
 
			- Longer  flexible cords.
 
            - Cord  extensions for existing units.
 
            - 4,  5 or 6-probe devices for multiple level control applications.
 
			
            
		  
          NOTE:  
          
- Do not use in flammable  solutions or in the presence of flammable gases. Not for use in deionized water, oil or other  non-conductive solutions.
 	
			
        
        
		