							Distributed by:
							
							Equipment Overview | Filter Pump Industries / Penguin Pump  | Process Technology
							 
							
							
							Digital Thermostats: DSL  Series, 1/16 DIN
					
					
	  	
			
					
					
			Features and Benefits
			
			IMPROVES PROCESS CONTROL: 
			- Easy to read dual LED displays (.3  inches high). Two set points (heating  and cooling). Provides precise temperature control for consistent plating and  etch rates in most aqueous processes.
 
          
            TEMPERATURE SENSOR: 
			- Fluoropolymer (FEP) covered 10-foot  (3m), 1000-ohm platinum RTD sensor included standard with the control. Provides extended service in corrosive  liquids and can be lengthened with ordinary copper hookup wire. 
 
          
          CORROSION RESISTANT ENCLOSURE: 
		  	
- 1/16 DIN size with NEMA 4X  (indoor), IP66, 3R and 12 rated front panel and sealed tactile switches.
 
          
          
          CERTIFICATIONS: 
		  
          
          CAPACITIES: 
		  
		  - Single pole, single throw switches rated at  3-amps for 120 through 240 volts. Three  switches: Set Point 1 (SP1), Set Point 2 (SP2), and alarm output (AL).
 
          - Adjustable  temperature range from -328°F (-200°C) to  4208°F (2320°C).
 
		  - +/- .25% full span, single digit accuracy.
 
		  - 14°F (-10°C) to  131°F (55°C) ambient temperature range.
 
		  - Universal power  supply: 100 to 240 VAC, 50 to 400 Hz.
 
		  - Single phase only.
 
		  
		  
          
          SPECIAL FEATURES: 
		  
- Auto tune PID, PID or On/Off  control with Auto/Manual operation.
 
		  
            SAFETY FEATURES: 
			
			- Non-volatile  memory.
 
			- Programmable high and/or low temperature  alarm output.
 
			- Programmable  high set point limit.
 
			- Sensor short and break protection.
 
			- Security  code restricted menu.
 
			
		  
		  
        CONSULT FACTORY FOR THE FOLLOWING OPTIONS:
          
            - 25-foot  (7.6m) and 50-foot (15.2m) sensors.
 
		  	- Combination  controls available for three phase service and larger heater loads.
 
            - Three  wire 100-ohm RTD sensors.
 
            - Type J, K, T, and R thermocouples.
 
			- Special  sensors required for temperatures above 500°F (260°C).
 
			- Scalable  voltage and current inputs.
 
            - 4-20 mA or 0-10VDC outputs for process  recording.
 
			- 4-20 mA or 15VDC control outputs.
 
			- Voltage, relay, logic/SSR and current  outputs.
 
			- RS232 or RS485 communication protocol.
 
			- Adaptor  panels for control retrofits.
 
			- Plastic enclosures for wall mounting.
 
			
        
        
		
		Downloads: