        				| MODEL | 
        				VOLTS | 
        				MAX AMPS | 
						Repl. Relay | 
						Repl. Trans. | 
						Repl. Sensor | 
        				SHIP WT. Lbs./(kg) | 
        			
        		
        		
        			
        				| C-DQ202 | 
        				240 | 
        				20 | 
						AHD-20-1 | 
						HDD50 2/1 | 
						RTD1000 | 
        				16 (7.3) | 
        			
					
        				| C-DQ204 | 
        				480 | 
        				20 | 
						AHD-20-1 | 
						HDD50 4/1 | 
						RTD1000 | 
        				16 (7.3) | 
        			
					
        				| C-DQ302 | 
        				240 | 
        				30 | 
						AHD-30-1 | 
						HDD50 2/1 | 
						RTD1000 | 
        				16 (7.3) | 
        			
        			
        				| C-DQ304 | 
        				480 | 
        				30 | 
						AHD-30-1 | 
						HDD50 4/1 | 
						RTD1000 | 
        				16 (7.3) | 
        			
					
        				| C-DQ502 | 
        				240 | 
        				50 | 
						AHD-50-1 | 
						HDD50 2/1 | 
						RTD1000 | 
        				17 (7.7) | 
        			
					
        				| C-DQ504 | 
        				480 | 
        				50 | 
						AHD-50-1 | 
						HDD50 4/1 | 
						RTD1000 | 
        				17 (7.7) | 
        			
        			
        				| C-DQ752 | 
        				240 | 
        				75 | 
						\AHD-75-1 | 
						HD100 2/1 | 
						RTD1000 | 
        				23 (10.4) | 
        			
					
        				| C-DQ754 | 
        				480 | 
        				75 | 
						AHD-75-1 | 
						HD100 4/1 | 
						RTD1000 | 
        				23 (10.4) | 
        			
					
        				| C-DQ902 | 
        				240 | 
        				90 | 
						AHD-90-1 | 
						HD100 2/1 | 
						RTD1000 | 
        				25 (11.3) | 
        			
					
        				| C-DQ904 | 
        				480 | 
        				90 | 
						AHD-90-1 | 
						HD100 4/1 | 
						RTD1000 | 
        				25 (11.3) | 
        			
					
        				| C-DQ1202 | 
        				240 | 
        				120 | 
						AHD-120-1 | 
						HD100 2/1 | 
						RTD1000 | 
        				27 (12.2) | 
        			
					
        				| C-DQ1204 | 
        				480 | 
        				120 | 
						AHD-120-1 | 
						HD100 4/1 | 
						RTD1000 | 
        				27 (12.2) | 
        			
					
        				| C-DQ1502 | 
        				240 | 
        				150 | 
						AHD-150-1 | 
						HDD150 2/1 | 
						RTD1000 | 
        				33 (15) | 
        			
					
        				| C-DQ1504 | 
        				480 | 
        				150 | 
						AHD-150-1 | 
						HDD150 4/1 | 
						RTD1000 | 
        				33 (15) | 
        			
				
        	
			
         
					
					Combination control consists of gasketed plastic enclosure, thermostat, 3 pole contactor transformer.
	  	
			
			
					
			Features and Benefits
			
			IMPROVES PROCESS CONTROL: 
			- Large (.56” high), easy to read  LED display.  Two set points (heating and  cooling). Provides precise control for consistent plating and etch rates in  most aqueous processes.
 
          
            TEMPERATURE SENSOR: 
			- Fluoropolymer (FEP) covered  10-foot (3m), 1000-ohm platinum RTD sensor included standard with the  control.  Provides extended service in  corrosive liquids and can be lengthened with ordinary copper hookup wire. 
 
          
          CORROSION RESISTANT ENCLOSURE: 
		  	
- NEMA 1, IP21, flame retardant and  gasketed plastic enclosure with stainless steel hardware.
 
          
          
          CERTIFICATIONS: 
		  
          
          CAPACITIES: 
		  
		  - Large switching capacities from 20 to 150  amps for up to 600 volts.
 
          - Adjustable temperature range from -40°F  (-40°C) to 999°F (538°C).
 
		  - +/- .25% full span, single digit accuracy.
 
		  - 20°F (-7°C) to 140°F (60°C) ambient  temperature range.
 
		  - Control transformer included.
 
		  - Single or three phase.
 
		  - Programmable standby temperature setting  for overnight  control and energy savings.
 
		  - Single pole, double throw switch rated at 2  amps for cooling loads.
 
		  
		  
            SAFETY FEATURES: 
			
			- Pre-wired P1 terminal blocks.
 
			- Non-volatile  memory.
 
			- Programmable  high alarm shutdown.
 
			- Programmable  high set point limit.
 
			- Sensor short and break protection.
 
			- Security  code restricted menu.
 
			
		  
		  
        CONSULT FACTORY FOR THE FOLLOWING OPTIONS:
          
            - 25-foot  (7.6m) and 50-foot (15.2m) sensors.
 
		  	- Pre-wired outlets  for plug-in heaters (some sizes).
 
            - Ground fault  protection of Equipment (GFPE) circuitry.
 
            - P2, P3 or P8 thermal protection systems.
 
			- Integrated liquid  level control components.
 
            - Front panel  mounted digital timers.
 
			- 4-20  mA outputs for process recording.
 
			- Special sensors  (required for temperatures above 500°F [260°C]).
 
			- Scalable voltage  and current inputs.
 
			- NEMA 4/4X enclosure (with internal heater for outdoor use.)
 
			- Three wire 100-ohm RTD sensors.
 
        
        
		