Process Technology Logo

Distributed by:

CDI Equipment Division logo

Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology

 

Digital Combination Controls: DLC Series

Digital Combination Controls: DLC Series

MODEL VOLTS MAX AMPS Repl. Relay Repl. Trans. Repl. Sensor SHIP WT. Lbs./(kg)
C-DLC202 240 20 AHD-20-1 HDD50 2-4/1 DLC-10L 16 (7.3)
C-DLC204 480 20 AHD-20-1 HDD50 2-4/1 DLC-10L 16 (7.3)
C-DLC302 240 30 AHD-30-1 HDD50 2-4/1 DLC-10L 16 (7.3)
C-DLC304 480 30 AHD-30-1 HDD50 2-4/1 DLC-10L 16 (7.3)
C-DLC502 240 50 AHD-50-1 HDD50 2-4/1 DLC-10L 17 (7.7)
C-DLC504 480 50 AHD-50-1 HDD50 2-4/1 DLC-10L 17 (7.7)
C-DLC752 240 75 AHD-75-1 HD100 2-4/1 DLC-10L 23 (10.4)
C-DLC754 480 75 AHD-75-1 HD100 2-4/1 DLC-10L 23 (10.4)
C-DLC902 240 90 AHD-90-1 HD100 2-4/1 DLC-10L 25 (11.3)
C-DLC904 480 90 AHD-90-1 HD100 2-4/1 DLC-10L 25 (11.3)
C-DLC1202 240 120 AHD-120-1 HD100 2-4/1 DLC-10L 27 (12.2)
C-DLC1204 480 120 AHD-120-1 HD100 2-4/1 DLC-10L 27 (12.2)
C-DLC1502 240 150 AHD-150-1 HDD150 2-4/1 DLC-10L 33 (15)
C-DLC1504 480 150 AHD-150-1 HDD150 2-4/1 DLC-10L 33 (15)

Combination control consists of gasketed plastic enclosure, thermostat, 3 pole contactor and transformer.

Features and Benefits

IMPROVES PROCESS CONTROL:
  • Large (.50” high), easy to read LED display. Provides precise control for consistent plating and etch rates in most aqueous processes.

TEMPERATURE SENSOR:
  • Fluoropolymer (FEP) covered 10-foot (3m), thermistor included standard with the control.  Provides extended service in corrosive liquids and can be lengthened with ordinary copper hookup wire.

CORROSION RESISTANT ENCLOSURE:
  • NEMA 1, IP21, flame retardant and gasketed plastic enclosure with stainless steel hardware.

CERTIFICATIONS:
  • cULus.

CAPACITIES:
  • Large switching capacities from 20 to 150 amps for up to 600 volts.
  • Adjustable temperature range from -58°F (-50°C) to 302°F (150°C).
  • +/- 1° full span, single digit accuracy.
  • 14°F (-10°C) to 158°F (70°C) ambient temperature range.
  • Control transformer included.
  • Single or three phase.

SAFETY FEATURES:
  • Non-volatile memory.
  • Pre-wired P1 terminal blocks.
  • Programmable high alarm shutdown.
  • Programmable high set point limit.
  • Sensor short and break protection.
  • Security code restricted menu.

CONSULT FACTORY FOR THE FOLLOWING OPTIONS:

  • Pre-wired outlets for plug-in heaters (some sizes).
  • Ground fault protection of equipment (GFPE) circuitry.
  • P2, P3 or P8 thermal protection systems.
  • Integrated liquid level control components.
  • Front panel mounted digital timers.
  • NEMA 4/4X enclosure (with internal heater for outdoor use.)
  • Celsius readout (must specify).

Downloads: