Process Technology Logo

Distributed by:

CDI Equipment Division logo

Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology

 

Immersion Heaters: Deep Tank, Metal Heater

Immersion Heaters: Deep Tank, Metal Heater
WATTS VOLTS HOT ZONE in./(mm) LENGTH in./(mm) PLAIN STEEL
Model Number
304 STAINLESS
Model Number
316 STAINLESS
Model Number
TITANIUM
Model Number
SHIP WT. Lbs./(kg)
12000 480 58 (1475) 96 (2440) P12496-** F12496-*-** S12496-*-** T12496-*-** 37 (17)
12000 480 58 (1475) 120 (3050) P124120-** F124120-*-** S124120-*-** T124120-*-** 45 (20)
12000 480 58 (1475) 144 (3655) P124144-** F124144-*-** S124144-*-** T124144-*-** 53 (24)
15000 480 76 (1930) 96 (2440) P15496-** F15496-*-** S15496-*-** T15496-*-** 37 (17)
15000 480 76 (1930) 120 (3050) P154120-** F154120-*-** S154120-*-** T154120-*-** 45 (20)
15000 480 76 (1930) 144 (3655) P154144-** F154144-*-** S154144-*-** T154144-*-** 53 (24)
18000 480 82 (2085) 96 (2440) P18496-** F18496-*-** S18496-*-** T18496-*-** 37 (17)
18000 480 82 (2085) 120 (3050) P184120-** F184120-*-** S184120-*-** T184120-*-** 45 (20)
18000 480 82 (2085) 144 (3655) P184144-** F184144-*-** S184144-*-** T184144-*-** 53 (24)
Three phase available as option. Add a dash before thermal protector designator. Heaters 15,000 watts and higher at 240 volts are available in three phase only.

Features and Benefits

SUPERIOR CHEMICAL RESISTANCE:
  • Materials available for use in most aqueous alkaline solutions, plating solutions and rinse tanks. Check solution recommendation chart or with your chemical supplier for proper sheath material selection.

RUGGED CONSTRUCTION:
  • Heavy wall metal sheaths and screw plug available in steel, 304 stainless steel, 316 stainless steel and titanium.

OUTSTANDING PERFORMANCE:
  • Watt densities of 35 watts per square inch (5.4 w/cm2) ensure long service life.

CORROSION RESISTANT HEAD:
  • Vapor resistant, flame retardant polypropylene terminal enclosure with 3-foot (.9m) flexible PVC liquid tight conduit.

SAFETY FEATURES:
  • Grounded construction.
  • Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).
  • Non-floating construction.

CERTIFICATIONS:
  • UL listed (except steel) to U.S. and Canadian safety requirements, and CE.

SIZES:
  • 12,000 watts to 18,000 watts.

VOLTAGES:
  • 240 to 600 volts. Single phase standard, three phase available.

CONSULT FACTORY FOR THE FOLLOWING:

  • Replaceable thermal protectors:
    • P4: for solutions from 180° F (82° C) to 230° F (110° C).
  • Resettable thermal protectors:
    • P2: bi-metal switch for solutions up to 180° F (82° C).
    • P6: for solutions from 180° F (82° C) to 230° F (110° C).
  • Special configurations and lengths.
  • Longer wire and conduit lengths.
  • Lower watt densities for highly viscous solutions.
  • Temperature and level controls sized to match the heater.

We recommend temperature controls and level controls for use with this immersion heater.

Downloads: