							Distributed by:
							
							Equipment Overview | Filter Pump Industries / Penguin Pump  | Process Technology
							 
							
							
							Immersion Heaters: Deep Tank, Metal Heater
					
					
					
					
            
        		
        			
        				| WATTS | 
        				VOLTS | 
        				HOT ZONE in./(mm) | 
        				LENGTH in./(mm) | 
        				PLAIN STEEL Model Number | 
        				304 STAINLESS Model Number | 
        				316 STAINLESS Model Number | 
        				TITANIUM Model Number | 
        				SHIP WT. Lbs./(kg) | 
        			
        		
        		
        			
        				| 12000 | 
        				480 | 
        				58 (1475) | 
        				96 (2440) | 
        				P12496-** | 
        				F12496-*-** | 
        				S12496-*-** | 
        				T12496-*-** | 
        				37 (17) | 
        			
        			
        				| 12000 | 
        				480 | 
        				58 (1475) | 
        				120 (3050) | 
        				P124120-** | 
        				F124120-*-** | 
        				S124120-*-** | 
        				T124120-*-** | 
        				45 (20) | 
        			
					
        				| 12000 | 
        				480 | 
        				58 (1475) | 
        				144 (3655) | 
        				P124144-** | 
        				F124144-*-** | 
        				S124144-*-** | 
        				T124144-*-** | 
        				53 (24) | 
        			
					
        				| 15000 | 
        				480 | 
        				76 (1930) | 
        				96 (2440) | 
        				P15496-** | 
        				F15496-*-** | 
        				S15496-*-** | 
        				T15496-*-** | 
        				37 (17) | 
        			
        			
        				| 15000 | 
        				480 | 
        				76 (1930) | 
        				120 (3050) | 
        				P154120-** | 
        				F154120-*-** | 
        				S154120-*-** | 
        				T154120-*-** | 
        				45 (20) | 
        			
					
        				| 15000 | 
        				480 | 
        				76 (1930) | 
        				144 (3655) | 
        				P154144-** | 
        				F154144-*-** | 
        				S154144-*-** | 
        				T154144-*-** | 
        				53 (24) | 
        			
					
        				| 18000 | 
        				480 | 
        				82 (2085) | 
        				96 (2440) | 
        				P18496-** | 
        				F18496-*-** | 
        				S18496-*-** | 
        				T18496-*-** | 
        				37 (17) | 
        			
        			
        				| 18000 | 
        				480 | 
        				82 (2085) | 
        				120 (3050) | 
        				P184120-** | 
        				F184120-*-** | 
        				S184120-*-** | 
        				T184120-*-** | 
        				45 (20) | 
        			
					
        				| 18000 | 
        				480 | 
        				82 (2085) | 
        				144 (3655) | 
        				P184144-** | 
        				F184144-*-** | 
        				S184144-*-** | 
        				T184144-*-** | 
        				53 (24) | 
        			
				
        	
			
         
					
					Three phase available as option. Add a dash before thermal protector designator. Heaters 15,000 watts and higher at 240 volts are available in three phase only. 
	  
	  				
	  	
			
					
					
			Features and Benefits
			
			SUPERIOR CHEMICAL RESISTANCE: 
			- Materials available for use in most aqueous  alkaline solutions, plating solutions and rinse tanks. Check solution recommendation chart or with your chemical supplier for proper sheath material selection.
 
			
            RUGGED CONSTRUCTION: 
			- Heavy wall metal sheaths and screw plug available in steel, 304 stainless steel, 316 stainless steel and titanium. 
 
          
          OUTSTANDING PERFORMANCE: 
		  	
- Watt densities of 35 watts per square inch (5.4 w/cm2) ensure long service life.
 
          
          CORROSION RESISTANT HEAD: 
		  	
- Vapor resistant, flame retardant polypropylene terminal enclosure with 3-foot (.9m) flexible PVC liquid tight conduit.
 
          
          SAFETY FEATURES:  
          
		  - Grounded construction.
 
          - Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).
 
          - Non-floating construction.
 
		  
          
          CERTIFICATIONS: 
		  
- UL listed (except steel) to U.S. and Canadian safety requirements, and CE.
 
          
          SIZES: 
		  
- 12,000 watts to 18,000 watts.
 
          
            VOLTAGES: 
			
- 240 to 600 volts. Single phase standard, three phase available.
 
			
        CONSULT FACTORY FOR THE FOLLOWING:
          
          - Replaceable thermal protectors: 
		  				 
            - P4: for solutions from 180° F (82° C) to 230° F (110° C).
 
           			  	
 
		  - Resettable thermal protectors: 
		  				 
            - P2: bi-metal switch for solutions up to 180° F (82° C).
 
            - P6: for solutions from 180° F (82° C) to 230° F (110° C).
 
           
						  
 
            - Special configurations and lengths.
 
            - Longer wire and conduit lengths.
 
            - Lower watt densities for highly viscous solutions.
 
			- Temperature and level controls sized to match the heater.
 
            
        
        
        We recommend temperature controls and level controls for use with this immersion heater.
		