Process Technology Logo

Distributed by:

CDI Equipment Division logo

Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology

 

Digital Combination Controls: DE Series

Digital Combination Controls: DE Series
MODEL VOLTS MAX AMPS Repl. Relay Repl. Trans. Repl. Sensor SHIP WT. Lbs./(kg)
C-DE202 240 20 AHD-20-1 HDD50 2-4/1 RTD1000 16 (7.3)
C-DE204 480 20 AHD-20-1 HDD50 2-4/1 RTD1000 16 (7.3)
C-DE302 240 30 AHD-40-1 HDD50 2-4/1 RTD1000 16 (7.3)
C-DE304 480 30 AHD-20-1 HDD50 2-4/1 RTD1000 16 (7.3)
C-DE502 240 50 AHD-50-1 HDD50 2-4/1 RTD1000 17 (7.7)
C-DE504 480 50 AHD-50-1 HDD50 2-4/1 RTD1000 17 (7.7)
C-DE752 240 75 AHD-75-1 HD100 2-4/1 RTD1000 23 (10.4)
C-DE754 480 75 AHD-75-1 HD100 2-4/1 RTD1000 23 (10.4)
C-DE902 240 90 AHD-90-1 HD100 2-4/1 RTD1000 25 (11.3)
C-DE904 480 90 AHD-90-1 HD100 2-4/1 RTD1000 25 (11.3)
C-DE1202 240 120 AHD-120-1 HD100 2-4/1 RTD1000 27 (12.2)
C-DE1204 480 120 AHD-120-1 HD100 2-4/1 RTD1000 27 (12.2)
C-DE1502 240 150 AHD-150-1 HDD150 2-4/1 RTD1000 33 (15)
C-DE1504 480 150 AHD-150-1 HDD150 2-4/1 RTD1000 33 (15)

Combination control consists of gasketed plastic enclosure, thermostat, 3 pole contactor and transformer.

Features and Benefits

IMPROVES PROCESS CONTROL:
  • Large (.56” high), easy to read LED display. Provides precise control for consistent plating and etch rates in most aqueous processes.

TEMPERATURE SENSOR:
  • Fluoropolymer (FEP) covered 10-foot (3m), 1000-ohm platinum RTD sensor included standard with the control.  Provides extended service in corrosive liquids and can be lengthened with ordinary copper hookup wire.

CORROSION RESISTANT ENCLOSURE:
  • NEMA 1, IP21, flame retardant and gasketed plastic enclosure with stainless steel hardware.

CERTIFICATIONS:
  • cULus.

CAPACITIES:
  • Large switching capacities from 20 to 150 amps for up to 600 volts.
  • Adjustable temperature range from -40°F (-40°C) to 999°F (538°C).
  • +/- .25% full span, single digit accuracy.
  • 20°F (-7°C) to 140°F (60°C) ambient temperature range.
  • Control transformer included.
  • Single or three phase.

SAFETY FEATURES:
  • Pre-wired P1 terminal blocks.
  • Non-volatile memory.
  • Programmable high alarm shutdown.
  • Programmable high set point limit.
  • Sensor short and break protection.
  • Security code restricted menu.

CONSULT FACTORY FOR THE FOLLOWING OPTIONS:

  • 25-foot (7.6m) and 50-foot (15.2m) sensors.
  • Pre-wired outlets for plug-in heaters (some sizes).
  • Ground fault protection of equipment (GFPE) circuitry.
  • P2, P3 or P8 thermal protection systems.
  • Integrated liquid level control components.
  • Front panel mounted digital timers.
  • Three wire 100-ohm RTD sensors.
  • Special sensors (required for temperatures above 500°F [260°C]).
  • Scalable voltage and current inputs.
  • NEMA 4/4X enclosure (with internal heater for outdoor use.)

Downloads: