Distributed by:
Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology
6HS Series, Six Element Stainless Steel Heaters
Watts |
Volts |
Hot Zone in./(mm) |
Length in./(mm) |
Model Number |
SHIP WT. Lbs./(kg) |
6000 |
240 |
10 (255) |
17 (430) |
6HS6217-** |
12 (5.5) |
6000 |
480 |
10 (255) |
17 (430) |
6HS6417-** |
12 (5.5) |
9000 |
240 |
16 (405) |
23 (585) |
6HS9223-** |
13 (6) |
9000 |
480 |
16 (405) |
23 (585) |
6HS9423-** |
13 (6) |
15000 |
240 |
20 (510) |
29 (735) |
6HS15229-** |
16 (7.5) |
15000 |
480 |
20 (510) |
29 (735) |
6HS15429-** |
16 (7.5) |
21000 |
240 |
25 (635) |
34 (865) |
6HS21234-** |
18 (8.5) |
21000 |
480 |
25 (635) |
34 (865) |
6HS21434-** |
18 (8.5) |
Three phase standard, single phase available as option. Add "-1" before thermal protector designator.
Features and Benefits
SUPERIOR CHEMICAL RESISTANCE:
- For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart or with your chemical supplier for proper sheath material selection.
RUGGED CONSTRUCTION:
- Heavy wall sheaths in 316 stainless steel.
OUTSTANDING PERFORMANCE:
- Watt densities of 40 watts/square inch (6.2 w/cm2) use minimal space and ensure long service life.
CORROSION RESISTANT HEAD:
- Vapor resistant, flame retardant polypropylene terminal enclosure with 3-foot (.9m) flexible PVC liquid tight conduit.
SAFETY FEATURES:
- Grounded construction.
- Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).
- Non-floating construction.
CERTIFICATIONS:
- cULus and CE (except 600 volts).
SIZES:
- 6,000 watts to 21,000 watts.
VOLTAGES:
- 240 to 600 volts. Three phase standard, single phase available.
CONSULT FACTORY FOR THE FOLLOWING:
- Replaceable thermal protectors:
- P4: for solutions from 180° F (82° C) to 230° F (110° C).
- Resettable thermal protectors:
- P2: bi-metal switch for solutions up to 180° F (82° C).
- P6: for solutions from 180° F (82° C) to 230° F (110° C).
- L-shaped and other special configurations and lengths.
- Longer wire and conduit lengths.
- Lower watt densities for highly viscous solutions.
- Titanium Elements.
- Temperature and level controls sized to match the heater.
We recommend temperature controls and level controls for use with this immersion heater.
Downloads: