Quartz Immersion Heaters with Metal Elements: 3QM Series

Quartz Immersion Heaters with Metal Elements: QM Series
WATTS VOLTS HOT ZONE in./(mm) LENGTH in./(mm) ELEMENT
Model Number
TUBE
Model Number
SINGLE GUARD
Model Number
TRIPLE GUARD
Model Number
SINGLE
SHIP WT. Lbs./(kg)
TRIPLE
SHIP WT. Lbs./(kg)
500 120 7 (180) 10 (255) QM.5110E QM.5110J-** QM10G 3QM10G 9 (4) 21 (10)
500 240 7 (180) 10 (255) QM.5210E QM.5210J-** QM10G 3QM10G 9 (4) 21 (10)
1000 120 7 (180) 11 (280) QM1111E QM1111J-** QM11G 3QM11G 10 (4.5) 22 (10)
1000 240 7 (180) 11 (280) QM1211E QM1211J-** QM11G 3QM11G 10 (4.5) 22 (10)
1000 120 7 (180) 17 (430) QM1117E QM1117J-** QM17G 3QM17G 11 (5) 26 (12)
1000 240 7 (180) 17 (430) QM1217E QM1217J-** QM17G 3QM17G 11 (5) 26 (12)
2000 240 12 (305) 17 (430) QM2217E QM2217J-** QM17G 3QM17G 11 (5) 26 (12)
2000 480 12 (305) 17 (430) QM2417E QM2417J-** QM17G 3QM17G 11 (5) 26 (12)
2000 240 12 (305) 23 (585) QM2223E QM2223J-** QM23G 3QM23G 14 (6.5) 30 (14)
2000 480 12 (305) 23 (585) QM2423E QM2423J-** QM23G 3QM23G 14 (6.5) 30 (14)
3000 240 18 (460) 23 (585) QM3223E QM3223J-** QM23G 3QM23G 14 (6.5) 30 (14)
3000 480 18 (460) 23 (585) QM3423E QM3423J-** QM23G 3QM23G 14 (6.5) 30 (14)
3000 240 18 (460) 29 (735) QM3229E QM3229J-** QM29G 3QM29G 17 (8) 34 (15.5)
3000 480 18 (460) 29 (735) QM3429E QM3429J-** QM29G 3QM29G 17 (8) 34 (15.5)
3500 240 21 (535) 29 (735) QM3.5229E QM3.5229J-** QM29G 3QM29G 17 (8) 34 (15.5)
3500 480 21 (535) 29 (735) QM3.5429E QM3.5429J-** QM29G 3QM29G 17 (8) 34 (15.5)
4000 240 28 (710) 35 (890) QM4235E QM4235J-** QM35G 3QM35G 20 (9) 38 (17)
4000 480 28 (710) 35 (890) QM4435E QM4435J-** QM35G 3QM35G 20 (9) 38 (17)
4000 240 28 (710) 41 (1040) QM4241E QM4241J-** QM41G 3QM41G 23 (10.5) 44 (20)
4000 480 28 (710) 41 (1040) QM4441E QM4441J-** QM41G 3QM41G 23 (10.5) 44 (20)
5000 240 33 (840) 41 (1040) QM5241E QM5241J-** QM41G 3QM41G 23 (10.5) 44 (20)
5000 480 33 (840) 41 (1040) QM5441E QM5441J-** QM41G 3QM41G 23 (10.5) 44 (20)
5000 240 33 (840) 47 (1195) QM5247E QM5247J-** QM47G 3QM47G 26 (12) 48 (22)
5000 480 33 (840) 47 (1195) QM5447E QM5447J-** QM47G 3QM47G 26 (12) 48 (22)
6000 240 39 (990) 47 (1195) QM6247E QM6247J-** QM47G 3QM47G 26 (12) 48 (22)
6000 480 39 (990) 47 (1195) QM6447E QM6447J-** QM47G 3QM47G 26 (12) 48 (22)
6000 240 39 (990) 52 (1320) QM6252E QM6252J-** QM52G 3QM52G 29 (13) 52 (24)
6000 480 39 (990) 52 (1320) QM6452E QM6452J-** QM52G 3QM52G 29 (13) 52 (24)
8000 240 49 (1245) 59 (1500) QM8259E QM8259J-** QM59G 3QM59G 31 (14) 55 (25)
8000 480 49 (1245) 59 (1500) QM8459E QM8459J-** QM59G 3QM59G 31 (14) 55 (25)
10000 240 62 (1575) 71 (1805) QM10271E QM10271J-** QM71G 3QM71G 34 (15.5) 65 (30)
10000 480 62 (1575) 71 (1805) QM10471E QM10471J-** QM71G 3QM71G 34 (15.5) 65 (30)
Heating element, quartz tube and single or triple guard all sold separately. NOTE: Not for use in hydrofluoric acid or alkaline solutions.

Features and Benefits

SUPERIOR CHEMICAL RESISTANCE:
  • For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart or with your chemical supplier for proper sheath material selection.

RUGGED CONSTRUCTION:
  • Heavy wall quartz sheath with replaceable metal element and polypropylene guards (complete assembly).

OUTSTANDING PERFORMANCE:
  • Watt densities of 25 watts per square inch (4 w/cm2) ensure long service life.

CORROSION RESISTANT HEAD:
  • Vapor resistant, flame retardant polypropylene terminal enclosure with 3-foot (.9m) flexible PVC liquid tight conduit.

SAFETY FEATURES:
  • Grounded construction.
  • Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).

CERTIFICATIONS:
  • UL listed to U.S. and Canadian safety requirements (less than 4000 watts), and 600 volt CSA only.

SIZES:
  • 500 watts to 10,000 watts.

VOLTAGES:
  • 120 to 600 volts. Single phase standard, three phase available.

CONSULT FACTORY FOR THE FOLLOWING:

  • Replaceable thermal protectors:
    • P4: for solutions from 180° F (82° C) to 230° F (110° C).
  • Resettable thermal protectors:
    • P2: bi-metal switch for solutions up to 180° F (82° C).
    • P6: for solutions from 180° F (82° C) to 230° F (110° C).
  • Special configurations and lengths.
  • Longer wire and conduit lengths.
  • Lower watt densities for highly viscous solutions.
  • Temperature and level controls sized to match the heater.
  • Three phase elements.
  • Fluoropolymer (PTFE) guards for chromic acid or solutions over 180°F (82°C).

We recommend temperature controls and level controls for use with this immersion heater.

Downloads: