Distributed by:

Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology
3HXOL Series, Multi Element L-Shaped Fluoropolymer (PTFE) Heaters

| WATTS |
VOLTS |
WIDTH in./(mm) |
HOT ZONE in./(mm) |
STD. VERT. LENGTH* in./(mm) |
MAX. COLD ZONE |
PROTECH MODEL NUMBER |
GUARD MODEL NUMBER |
SHIP WT. Lbs./(kg) |
| 3000 |
240 |
7 (180) |
13 (330) |
18 (460) |
36 (915) |
3HXOL3207-13-R*-** |
3HXOL07-13-R* |
20 (9.5) |
| 3000 |
480 |
7 (180) |
13 (330) |
18 (460) |
36 (915) |
3HXOL3407-13-R*-** |
3HXOL07-13-R* |
20 (9.5) |
| 4500 |
240 |
9 (230) |
11 (280) |
18 (460) |
35 (890) |
3HXOL4.5209-11-R*-** |
3HXOL09-11-R* |
21 (9.5) |
| 4500 |
480 |
9 (230) |
11 (280) |
18 (460) |
35 (890) |
3HXOL4.5409-11-R*-** |
3HXOL09-11-R* |
21 (9.5) |
| 6000 |
240 |
10 (250) |
19 (485) |
18 (460) |
35 (890) |
3HXOL6210-19-R*-** |
3HXOL10-19-R* |
22 (10) |
| 6000 |
480 |
10 (250) |
19 (485) |
18 (460) |
35 (890) |
3HXOL6410-19-R*-** |
3HXOL10-19-R* |
22 (10) |
| 9000 |
240 |
10 (250) |
23 (585) |
18 (460) |
35 (890) |
3HXOL9210-23-R*-** |
3HXOL10-23-R* |
36 (16.5) |
| 9000 |
480 |
10 (250) |
23 (585) |
18 (460) |
35 (890) |
3HXOL9410-23-R*-** |
3HXOL10-23-R* |
36 (16.5) |
| 12000 |
240 |
10 (250) |
30 (915) |
18 (460) |
35 (890) |
3HXOL12210-30-R*-** |
3HXOL10-30-R* |
42 (22) |
| 12000 |
480 |
10 (250) |
30 (915) |
18 (460) |
35 (890) |
3HXOL12410-30-R*-** |
3HXOL10-30-R* |
42 (22) |
| 15000 |
240 |
10 (250) |
36 (915) |
18 (460) |
31 (790) |
3HXOL15210-36-R*-** |
3HXOL10-36-R* |
48 (22) |
| 15000 |
480 |
10 (250) |
36 (915) |
18 (460) |
31 (790) |
3HXOL15410-36-R*-** |
3HXOL10-36-R* |
48 (22) |
| 18000 |
240 |
10 (250) |
42 (1065) |
18 (460) |
25 (635) |
3HXOL18210-42-R*-** |
3HXOL10-42-R* |
54 (24.5) |
| 18000 |
480 |
10 (250) |
42 (1065) |
18 (460) |
25 (635) |
3HXOL18410-42-R*-** |
3HXOL10-42-R* |
54 (24.5) |
Three phase standard.
Features and Benefits
SUPERIOR CHEMICAL RESISTANCE:
- Inert to most aqueous acid, alkaline, anodizing and pickling solutions up to 212°F (100°C).
RUGGED CONSTRUCTION:
- Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purged systems. Guaranteed 100% pinhole free.
OUTSTANDING PERFORMANCE:
- Low watt density design (10 watts/square inch, 1.5 w/cm2) for long service life.
EVEN HEATING:
- Bottom design for even heating and varying liquid levels.
CORROSION RESISTANT HEADS: Vapor resistant, flame retardant polypropylene terminal enclosures each with 3-foot (.9m) flexible PVC liquid tight conduits.
SAFETY FEATURES:
- Grounded internal metal element.
- Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).
- Non-floating construction.
CERTIFICATIONS: cULus and CE (Except 600 volts).
SIZES:3,000 watts to 18,000 watts.
VOLTAGES::
- 120 to 600 volts.
- Three phase standard, single phase available.
CONSULT FACTORY FOR THE FOLLOWING:
- Resettable thermal protectors:
- P2: bi-metal switch for solutions up to 180° F (82° C).
- P8: type-J thermocouple for solutions from 180° F (82° C) to 210° F (99° C).
- P3: type-J thermocouple for solutions from 210° F (99° C) to 250° F (121° C).
- Longer vertical lengths (cold zones).
- Polypropylene guards: recommended for applications up to 180°F (82°C) (sold separately).
- Fluoropolymer (PTFE) guards: recommended for chromic acid or solutions over 180° F (82° C) (sold separately).
- Special configurations.
- Longer wire and conduit lengths.
- Flexible continuous fluoropolymer leads (P3 protector only).
- Lower watt densities for highly viscous solutions and technical acids.
- Temperature and level controls sized to match the heater.
- Single phase power.
We recommend temperature controls and level controls for use with this immersion heater.
Downloads: