Process Technology Logo

Distributed by:

CDI Equipment Division logo

Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology

 

3HXO Series, Multi Element Fluoropolymer (PTFE) Heaters

3HXO Series, Multi Element Fluoropolymer (PTFE) Heaters
WATTS VOLTS WIDTH in./(mm) HEATER PAD LENGTH in./(mm) OVERALL LENGTH* in./(mm) MAX. COLD ZONE PROTECH MODEL NUMBER GUARD MODEL NUMBER SHIP WT. Lbs./(kg)
1500 120 10(255) 6(155) 11(280) 36(915) 3HXO1.5110-06-11-** 3HXO10-11G 15(7)
1500 240 10(255) 6(155) 11(280) 36(915) 3HXO1.5210-06-11-** 3HXO10-11G 15(7)
3000 240 10(255) 6(155) 11(280) 36(915) 3HXO3210-06-11-** 3HXO10-11G 20(9.5)
3000 480 10(255) 6(155) 11(280) 36(915) 3HXO3410-06-11-** 3HXO10-11G 20(9.5)
4500 240 10(255) 9.5(245) 17(430) 35(890) 3HXO4.5210-9.5-17-** 3HXO10-17G 21(9.5)
4500 480 10(255) 9.5(245) 17(430) 35(890) 3HXO4.5410-9.5-17-** 3HXO10-17G 21(9.5)
6000 240 12(305) 9.5(245) 17(430) 35(890) 3HXO6212-10.5-17-** 3HXO12-17G 21(9.5)
6000 480 12(305) 9.5(245) 17(430) 35(890) 3HXO6412-10.5-17-** 3HXO12-17G 21(9.5)
9000 240 12(305) 16(405) 23(585) 35(890) 3HXO9212-16-23-** 3HXO12-23G 36(16.5)
9000 480 12(305) 16(405) 23(585) 35(890) 3HXO9412-16-23-** 3HXO12-23G 36(16.5)
12000 240 12(305) 20.5(520) 29(735) 35(890) 3HXO12212-20.5-29-** 3HXO12-29G 42(20)
12000 480 12(305) 20.5(520) 29(735) 35(890) 3HXO12412-20.5-29-** 3HXO12-29G 42(20)
15000 240 12(305) 25(635) 35(890) 31(790) 3HXO15212-25-35-** 3HXO12-35G 48(22)
15000 480 12(305) 25(635) 35(890) 31(790) 3HXO15412-25-35-** 3HXO12-35G 48(22)
18000 240 12(305) 29(735) 40(1015) 25(635) 3HXO18212-29-40-** 3HXO12-40G 54(24.5)
18000 480 12(305) 29(735) 40(1015) 25(635) 3HXO18412-29-40-** 3HXO12-40G 54(24.5)

Three phase standard.

Features and Benefits

SUPERIOR CHEMICAL RESISTANCE:
  • Inert to most aqueous acid, alkaline, anodizing and pickling solutions up to 212°F (100°C).

RUGGED CONSTRUCTION:
  • Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purged systems. Guaranteed 100% pinhole free.

OUTSTANDING PERFORMANCE:
  • Low watt density design (10 watts/square inch, 1.5 w/cm2) for long service life.

CORROSION RESISTANT HEADS: Vapor resistant, flame retardant polypropylene terminal enclosures each with 3-foot (.9m) flexible PVC liquid tight conduits.

SAFETY FEATURES:
  • Grounded internal metal element.
  • Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).
  • Non-floating construction.

CERTIFICATIONS: cULus and CE.

SIZES:1,500 watts to 18,000 watts.

VOLTAGES::
  • 120 to 600 volts.
  • Three phase standard, single phase available.

CONSULT FACTORY FOR THE FOLLOWING:

  • Resettable thermal protectors:
    • P2: bi-metal switch for solutions up to 180° F (82° C).
    • P8: type-J thermocouple for solutions from 180° F (82° C) to 210° F (99° C).
    • P3: type-J thermocouple for solutions from 210° F (99° C) to 250° F (121° C).
  • Longer vertical lengths (cold zones).
  • Polypropylene guards: recommended for applications up to 180°F (82°C) (sold separately).
  • Fluoropolymer (PTFE) guards: recommended for chromic acid or solutions over 180° F (82° C) (sold separately).
  • Special configurations.
  • Longer wire and conduit lengths.
  • Flexible continuous fluoropolymer leads (P3 protector only).
  • Lower watt densities for highly viscous solutions and technical acids.
  • Temperature and level controls sized to match the heater.

NOTE: Hot zone extends 2" (51mm) above the heater pad length.

We recommend temperature controls and level controls for use with this immersion heater.

Downloads: