3HX Series, Three Element Stainless Steel Heaters

3HX Series, Three Element Fluoropolymer (PTFE) Heaters
WATTS VOLTS HOT ZONE in./(mm) OVERALL LENGTH in./(mm) PROTECH MODEL NUMBER GUARD MODEL NUMBER SHIP WT. Lbs./(kg)
1000 120 10(280) 17(430) 3HX1117-** HX/3HX17G 10(4.5)
1000 240 10(280) 17(430) 3HX1217-** HX/3HX17G 10(4.5)
1500 120 16(405) 23(585) 3HX1.5123-** HX/3HX23G 11(5)
1500 240 16(405) 23(585) 3HX1.5223-** HX/3HX23G 11(5)
1500 480 16(405) 23(585) 3HX1.5423-** HX/3HX23G 11(5)
2000 240 22(560) 29(735) 3HX2229-** HX/3HX29G 12(5.5)
2000 480 22(560) 29(735) 3HX2429-** HX/3HX29G 12(5.5)
3000 240 29(735) 35(890) 3HX3235-** HX/3HX35G 14(6.5)
3000 480 29(735) 35(890) 3HX3435-** HX/3HX35G 14(6.5)
4000 240 39(990) 47(1195) 3HX4247-** HX/3HX47G 17(8)
4000 480 39(990) 47(1195) 3HX4447-** HX/3HX47G 17(8)
5000 240 48(1220) 59(1500) 3HX5259-** HX/3HX59G 20(9)
5000 480 48(1220) 59(1500) 3HX5459-** HX/3HX59G 20(9)
6000 240 56(1420) 68(1725) 3HX6268-** HX/3HX68G 23(10.5)
6000 480 56(1420) 68(1725) 3HX6468-** HX/3HX68G 23(10.5)

Three phase standard.

Features and Benefits

SUPERIOR CHEMICAL RESISTANCE:
  • Inert to most aqueous acid, alkaline, anodizing and pickling solutions up to 212°F (100°C).

RUGGED CONSTRUCTION:
  • Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purged systems. Guaranteed 100% pinhole free.

OUTSTANDING PERFORMANCE:
  • Low watt density design (10 watts/square inch, 1.5 w/cm2) for long service life.

CORROSION RESISTANT HEAD:
  • Vapor resistant, flame retardant polypropylene terminal enclosure with 3-foot (.9m) flexible PVC liquid tight conduit.

SAFETY FEATURES:
  • Grounded internal metal element.
  • Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).
  • Non-floating construction.

CERTIFICATIONS:
  • UL listed to U.S. and Canadian safety requirements, and CE.

SIZES:
  • 1,000 watts to 6,000 watts.

VOLTAGES:
  • 120 to 600 volts (600 watts CSA only). Three phase standard, single phase available.

CONSULT FACTORY FOR THE FOLLOWING:

  • Resettable thermal protectors:
    • P2: bi-metal switch for solutions up to 180° F (82° C).
    • P8: type-J thermocouple for solutions from 180° F (82° C) to 230° F (110° C).
    • P3: type-J thermocouple for solutions from 230° F (110° C) to 300° F (150° C).
  • Longer vertical lengths (cold zones).
  • Polypropylene guards: recommended for applications up to 180°F (82°C), sold separately.
  • Fluoropolymer (PTFE) guards: recommended for chromic acid or solutions over 180° F (82° C), sold separately.
  • Special configurations.
  • Longer wire and conduit lengths.
  • Lower watt densities for highly viscous solutions and technical acids.
  • Temperature and level controls sized to match the heater.

We recommend temperature controls and level controls for use with this immersion heater.