Distributed by:
Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology
3HX Series, Three Element Stainless Steel Heaters
WATTS |
VOLTS |
HOT ZONE in./(mm) |
OVERALL LENGTH in./(mm) |
PROTECH MODEL NUMBER |
GUARD MODEL NUMBER |
SHIP WT. Lbs./(kg) |
1000 |
120 |
10(280) |
17(430) |
3HX1117-** |
HX/3HX17G |
10(4.5) |
1000 |
240 |
10(280) |
17(430) |
3HX1217-** |
HX/3HX17G |
10(4.5) |
1500 |
120 |
16(405) |
23(585) |
3HX1.5123-** |
HX/3HX23G |
11(5) |
1500 |
240 |
16(405) |
23(585) |
3HX1.5223-** |
HX/3HX23G |
11(5) |
1500 |
480 |
16(405) |
23(585) |
3HX1.5423-** |
HX/3HX23G |
11(5) |
2000 |
240 |
22(560) |
29(735) |
3HX2229-** |
HX/3HX29G |
12(5.5) |
2000 |
480 |
22(560) |
29(735) |
3HX2429-** |
HX/3HX29G |
12(5.5) |
3000 |
240 |
29(735) |
35(890) |
3HX3235-** |
HX/3HX35G |
14(6.5) |
3000 |
480 |
29(735) |
35(890) |
3HX3435-** |
HX/3HX35G |
14(6.5) |
4000 |
240 |
39(990) |
47(1195) |
3HX4247-** |
HX/3HX47G |
17(8) |
4000 |
480 |
39(990) |
47(1195) |
3HX4447-** |
HX/3HX47G |
17(8) |
5000 |
240 |
48(1220) |
59(1500) |
3HX5259-** |
HX/3HX59G |
20(9) |
5000 |
480 |
48(1220) |
59(1500) |
3HX5459-** |
HX/3HX59G |
20(9) |
6000 |
240 |
56(1420) |
68(1725) |
3HX6268-** |
HX/3HX68G |
23(10.5) |
6000 |
480 |
56(1420) |
68(1725) |
3HX6468-** |
HX/3HX68G |
23(10.5) |
Three phase standard.
Features and Benefits
SUPERIOR CHEMICAL RESISTANCE:
- Inert to most aqueous acid, alkaline, anodizing and pickling solutions up to 212°F (100°C).
RUGGED CONSTRUCTION:
- Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purged systems. Guaranteed 100% pinhole free.
OUTSTANDING PERFORMANCE:
- Low watt density design (10 watts/square inch, 1.5 w/cm2) for long service life.
CORROSION RESISTANT HEAD:
- Vapor resistant, flame retardant polypropylene terminal enclosure with 3-foot (.9m) flexible PVC liquid tight conduit.
SAFETY FEATURES:
- Grounded internal metal element.
- Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).
- Non-floating construction.
CERTIFICATIONS:
- UL listed to U.S. and Canadian safety requirements, and CE.
SIZES:
- 1,000 watts to 6,000 watts.
VOLTAGES:
- 120 to 600 volts (600 watts CSA only). Three phase standard, single phase available.
CONSULT FACTORY FOR THE FOLLOWING:
- Resettable thermal protectors:
- P2: bi-metal switch for solutions up to 180° F (82° C).
- P8: type-J thermocouple for solutions from 180° F (82° C) to 230° F (110° C).
- P3: type-J thermocouple for solutions from 230° F (110° C) to 300° F (150° C).
- Longer vertical lengths (cold zones).
- Polypropylene guards: recommended for applications up to 180°F (82°C), sold separately.
- Fluoropolymer (PTFE) guards: recommended for chromic acid or solutions over 180° F (82° C), sold separately.
- Special configurations.
- Longer wire and conduit lengths.
- Lower watt densities for highly viscous solutions and technical acids.
- Temperature and level controls sized to match the heater.
We recommend temperature controls and level controls for use with this immersion heater.