Equipment Overview | Filter Pump Industries / Penguin Pump | Process Technology
3HS Series, Three Element Stainless Steel Heaters
Watts |
Volts |
Hot Zone in./(mm) |
Length in./(mm) |
Model Number |
SHIP WT. Lbs./(kg) |
3000 |
240 |
11 (280) |
17 (430) |
3HS3217-** |
9 (4) |
3000 |
480 |
11 (280) |
17 (430) |
3HS3417-** |
9 (4) |
4500 |
240 |
16 (405) |
23 (585) |
3HS4.5223-** |
10 (4.5) |
4500 |
480 |
16 (405) |
23 (585) |
3HS4.5423-** |
10 (4.5) |
7500 |
240 |
21 (535) |
29 (735) |
3HS7.5229-** |
12 (5.5) |
7500 |
480 |
21 (535) |
29 (735) |
3HS7.5429-** |
12 (5.5) |
10500 |
240 |
26 (660) |
34 (865) |
3HS10.5234-** |
14 (6.5) |
10500 |
480 |
26 (660) |
34 (865) |
3HS10.5434-** |
14 (6.5) |
Three phase standard, single phase available as option. Add "-1" before thermal protector designator.
Features and Benefits
SUPERIOR CHEMICAL RESISTANCE:
- For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart or with your chemical supplier for proper sheath material selection.
RUGGED CONSTRUCTION:
- Heavy wall sheaths in 316 stainless steel.
OUTSTANDING PERFORMANCE:
- Watt densities of 40 watts/square inch (6.2 w/cm2) use minimal space and ensure long service life.
CORROSION RESISTANT HEAD:
- Vapor resistant, flame retardant polypropylene terminal enclosure with 3-foot (.9m) flexible PVC liquid tight conduit.
SAFETY FEATURES:
- Grounded construction.
- Thermal protector built in. Replaceable P1 protector standard for solutions up to 180° F (82° C).
- Non-floating construction.
CERTIFICATIONS:
- cULus and CE (except 600 volts).
SIZES:
- 3,000 watts to 10,500 watts.
VOLTAGES:
- 240 to 600 volts. Three phase standard, single phase available.
CONSULT FACTORY FOR THE FOLLOWING:
- Replaceable thermal protectors:
- P4: for solutions from 180° F (82° C) to 230° F (110° C).
- Resettable thermal protectors:
- P2: bi-metal switch for solutions up to 180° F (82° C).
- P6: for solutions from 180° F (82° C) to 230° F (110° C).
- Special configurations and lengths.
- Longer wire and conduit lengths.
- Lower watt densities for highly viscous solutions.
- Titanium Elements.
- Temperature and level controls sized to match the heater.
We recommend temperature controls and level controls for use with this immersion heater.