Hull Cell Equipment
							Equipment Overview | Filter Pump Industries / Penguin Pump  | Process Technology
							 
                			The cell, called a Hull Cell, is a miniature plating unit for producing a cathode deposit that records the character of electroplate at all current 
							densities within the operating range. It is among the most useful tools available to the plating chemist for control of plating baths. It is an 
							indispensable adjunct to standard analytical methods, enabling the skilled operator to determine and control the effects of addition agents, impurities 
							and purification treatments on the plating electrolyte, many of which can be determined by no other method. Practically every plating solution can be 
							controlled or evaluated to varying degrees by the use of the Hull Cell. CDI offers a complete selection of Hull Cells, accessories and related 
							equipment to enable the plater to effectively use this plating process control method.
                			Please call for controls / accesories or special applications.
                			 
                			
                			Hull Cell Equipment
							
							
							
								
								
									
										
                						- Kocour anodes for Hull Cell tests are of high quality. Certified trace impurity analysis available.
 
                						- Comes in brass, copper, high phosphorous copper, lead, nickel, silver, tin/lead (60/40), tin/lead (90/10), 
												  316 SS and platinized titanium.
 
                						- One size can be used in either the 267 ml, or the 1000 ml size Hull Cell. Size is 2.75" by 2.75"
 
                						- Also available are titanium baskets and Poly bags for the anodes and baskets which provide protection against roughness in the Hull Cell deposit.
 
                						
                						
                						
                						More Information:
														 
														 
									 
								 
							 
							
								
								
									
										
                    					
                						- Kocour Cathodes are heavy gauge, highly polished to a mirror finish with the face surface fully protected by plastic.
 
                						- Comes in brass, copper, high phosphorous copper, lead, nickel, silver, tin/lead (60/40), tin/lead (90/10), 
												  316 SS and platinized titanium.
 
                						- Available in Brass, Copper and Steel (zinc coated), in two sizes for the 267 ml and the 1000 ml Hull Cell. Can be purchased individually, 
										as multiples of "Each", or in a box of 50(267ml) or 100(1000ml).
 
                						
                						
                						
                						More Information:
														 
														 
								 
							 
							
							
								
								
									
										
                    						
                						- In 1935, the E.I. duPont De Nemours Co. asked Kocour Company to manufacture a plating test cell developed in their laboratory. The cell, 
										called a Hull Cell, is a miniature plating unit for producing a cathode deposit that records the character of electroplate at all current densities 
										within the operating range.
 
                						- It is among the most useful tools available to the plating chemist for control of plating baths. It is an indispensable adjunct to standard 
										analytical methods, enabling the skilled operator to determine and control the effects of addition agents, impurities and purification treatments 
										on the plating electrolyte, many of which can be determined by no other method. Practically every plating solution can be controlled or evaluated to 
										varying degrees by the use of the Hull Cell.
 
                						
                						
                						
                						Product Features:
										
			- Brass
Color Control
Free Cyanide Control
Brightener Control 
			- 
Cadmium
Brightener Control
Detection of Organic Impurities
Detection of Carbonate Buildup
Control of Inorganic Impurities - especially Lead, Chromium, Tin and  Copper 
			- 
Chromium
Outstanding for Control of Catalyst Ratio 
Detection of Chloride and Metal Contamination 
			- 
Copper
Free Cyanide Content
 
Lead, Zinc and Chromium contamination
Carbonate Addition Agents 
			- 
Gold
Color Control
Addition Agents 
			- 
Nickel
Primary and Secondary Addition Agents
Pitting
Organic Decomposition Products
Copper, Zinc, Chromium or Iron Impurities
pH Brittleness 
			- 
Silver
Free Cyanide and Silver Content
Operating pH
Addition Agents 
			- 
Tin
Caustic Content
Addition Agents 
			- 
Zinc
Sodium Cyanide to Zinc Metal Ratio
Zinc Content
Copper, Lead, Cadmium and Tin Impurities
Effect of Purification Treatments
Addition Agents 
		
										More Information:
														 
									 
								 
							 
							
								
								
									
										
                    						
                						- The reciprocating agitator is designed to simulate cathode rod agitation (non-air agitation) in Hull Cell Tests.
 
                						- Comes in brass, copper, high phosphorous copper, lead, nickel, silver, tin/lead (60/40), tin/lead (90/10), 
												  316 SS and platinized titanium.
 
                						- Operates 110 volt, 60 Hz, AC.
 
										- Also available in 220 Volt.
 
                						
                						
                						
                						More Information:
														 
									 
								 
							 
							
							
								
								
									
											
                						- Kocour Rectifiers for Hull Cell Testing are expressly designed units which utilize filtered circuits capable of 
										continuously producing minimum AC ripple. This filtered current output is essential for testing many plating baths.
 
                						- Kocour Rectifiers are strongly recommended for Hull Cell tests because results are misleading when single phase unfiltered current is used.
 
                						
                						
                						
                						More Information:
														 
									 
								 
							 
							
								
								
									
										
                						- Universal Timers GraLab's Universal Timers feature an 8" dial with large numerals for elapsed time. Two separate 3-wire outlet 
										receptacles are provided for automatic switching of external appliances. Used for Hull Cell Test timing as well as general laboratory timing uses.
 
                						
                						
                						
                						More Information: